Crushing Test load as given in MS 881 : 1991 are reproduced for ready reference.

 

 

Land Drainage Pipes - For all Diameters:

Works Proof Load - 20kN per metre of effective length.
Maximum load - 25kN per metre of effective length

 

Crushing test load for 'Sewerage' pipes

Kilonewtons per metre of effective length

Nominal
size of
pipe
Class L Class M Class H
DN Works
proof
load
Maxi-
mum
load
Works
proof
load
Maxi-
mum
load
Works
proof
load
Maxi-
mum
load
150 20 25
225 20 25
300 20 25 23 29
375 20 25 31 39 36 45
450 20 25 35 44 41 52
525 20 25 38 48 46 58
600 20 25 46 58 54 68
675 20 25 50 63 60 75
750 38 48 53 67 65 81
825 41 52 58 72 69 86
900 46 58 67 84 85 106
975 48 60 72 90 91 114
1050 51 64 76 95 96 120
1125 53 67 82 103 106 133
1200 58 72 87 109 110 138
1350 63 79 96 120 122 153
1500 69 87 1047 130 132 165
1650 75 94 116 145 146 183
1800 82 103 124 155 158 198

 

 